<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-07 08-55-55
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 41 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 16 kHz 7375 0,5966
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,1 dBr 4,74 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 16 kHz MIN: 13 kHz % above 76 kHz: 0,5966 Acquired: 2026/05/07 8.54.50 Total samples: 7375 Equivalent time: 0:06:08 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 6,1 dBr MIN: 3,1 dBr AVE: 4,74 dBr % above 12,2 dBr: 0,0 Last value: 5,4 dBr (2026/05/07 8.54.50) 08.40 08.42 08.44 08.46 08.48 08.50 08.52 08.54 0 2 4 6 Pm [dBr]